Proof Positive® Span Cable

PROOF POSITIVE® BONDED SHIELD IRRIGATION CABLE FOR IRRIGATION CABLE FOR POWER & CONTROL CIRCUTS | SPEC P7065PPS

INSULATION: Polyvinyl Chloride & Nylon
OUTER JACKET: Polyethylene
SIZES: 10 AWG 4/C, 14 AWG 7/C with Drain
1386896987_file_extension_pdfDownload Spec Sheet

 

View Product Details

1.0 Application

  1. 1.1

    600V aluminum shielded drain cable specifically designed to power electric motor driven irrigation machines. The cable contains a tracer ID tape and yellow jacket to prove ownership and deter theft.

  2. 1.2

    The 1/8" Proof Positive marker tape is pre-printed with highly visible license code, serial numbers and www.2idcu.com every 3". A bright yellow UV resistant jacket provides a deterrent to theft and alerts recyclers to run a database check at www.2idcu.com to verify rightful owner.

2.0 Construction

  1. 2.1

  2. 2.2

    Conductor:Stranded, soft annealed uncoated copper conforming to ASTM B-8.

  3. 2.3

    Insulation:Polyvinyl Chloride and Nylon conforming to UL Style THHN/THWN. Other insulation types may be allowed if they conform to UL1263.

  4. 2.4

    Cable Assembly:Insulated conductors are cabled together in a suitable lay with an optional but not required 1 mil mylar tape wrapped helically over the assembly, 10% minimum overlap.

  5. 2.5

    Inner Jacket:Polyvinyl chloride conforming to IPCEA S-61-402 and NEMA WC5 - minimum average wall thickness .030”.

  6. 2.6

    Color Coding:10 AWG - Red, Black, Blue, Green/Yellow stripe 
    14 AWG - Brown, White, Orange,Yellow, Purple, Pink, Yellow/Red stripe.

  7. Stripes must cover 30-50% of the insulated conductor circumference. If the insulation is type THHN/THWN/TFN/ TFFN, it must be added to the PVC layer. For single layer insulations, the stripe must be extruded. Stripes may be longitudinal or spiral.

  8. 2.7

    Shield:.008 corrugated or smooth aluminum specially coated and applied in order to bond to the outer jacket.

  9. 2.8

    Outer Jacket:Sunlight resistant Polyethelene (yellow) conforming to IPCEA S-61-402, NEMA WC5 and UL 1263. Minimum Average .050”

  10. 2.9

    O.D.:.700”-.800” nominal.

  11. 2.10

    Surface Print:PROOF POSITIVE(R) SPAN CABLE SHIELDED “10/4 + 14/7”IRRIGATION CABLE 600V NEC ART 675 (UL) DIR. BUR (MM/DD/YYYY) Sequential footage marks TRACEABLE